How to change BMC IP address
Description
This document will describe how to change the BMC IP address via Lenovo XClarity Controller (XCC), and the Lenovo XClarity Provisioning Manager (LXPM) text setup interface.
The Lenovo XClarity Controller (XCC) is the next generation management controller that replaces the baseboard management controller (BMC) for Lenovo ThinkSystem servers. It is the follow-on to the Integrated Management Module II (IMM2) service processor that consolidates the service processor functionality, Super I/O, video controller, and remote presence capabilities into a single chip on the server system board.
Applicable Brands
- Lenovo ThinkSystem
- Lenovo ThinkAgile
System Is Configured With
Lenovo XClarity Controller
Solution
Change BMC IP by LXCC
1. Connect to the Lenovo XClarity Controller by using the web browser
2. Login to the LXCC
3. In the "System Information and settings" panel, click the right arrow of BMC IP address or click "BMC Configuration" → "Network" on the left navigation panel
4. Set the "Host Name", "Method", IP address, Network mask, gateway
5. Click "Apply" to enable the setting.
YouTube
YouKu
Change BMC IP by text tool setup
1. Press F1 to get into text tool setup during system start up
2. Enter "BMC settings" → "Network settings"
3. Set the "Hostname", "DHCP control", "IP Address", "Subnet mask", "Default gateway"
4. Scroll to the bottom, "Save network settings"
Related Article
Lenovo XClarity Controller (XCC) Support on ThinkSystem Servers
Tidak ada komentar: